Principal Investigator Dr. Howard Epstein shares insights on how buildings affect ground temperature and permafrost thaw at sites across Utqiaġvik in a meeting at
Ilisaġvik College on May 27, 2026. (Courtesy: Ilisaġvik College)
Research Notes
By Howard Epstein, PhD | Oct 2026
How do Urban Heat Islands manifest in the Arctic?
An urban heat island (UHI) is a metropolitan area that is significantly warmer than surrounding rural areas because buildings, roads, and other human modifications to the landscape alter how heat is absorbed and retained. Prior studies in Utqiaġvik, Alaska found a minimally significant heat island effect in summer and a more prominent effect (~2 °C) in the winter.
To understand the dynamics of urban heating at fine spatio-temporal scales, we established a network of micrometeorological sensor arrays to continuously measure ground temperature, ground moisture, air temperature, wind speed/direction, and solar radiation at three locations around town (hospital, utilities, residential) and one tundra site (Barrow Environmental Observatory) outside of town.
Looking at four years of data (2022-2025), our results show a very strong urban heat island effect around infrastructure down to approximately 50-65 cm depth that varies by aspect (location around the building) and how the building was constructed. Averaged across all sites, summer air temperatures were 3.8 °C greater in the urban settings compared to the tundra site, while near-surface ground temperatures (at 10cm depth) were an average of 2.5 °C greater in the urban settings.
Summer air temperatures were 3.8 °C greater in urban settings compared to the tundra site, while urban near-surface ground temperatures were an average of 2.5 °C greater.
Interestingly, at most urban locations, temperatures at greater depths (e.g., below ~65 cm) were substantially colder than corresponding depths at the tundra site, possibly due to heat lost to cold ground directly beneath the buildings.
Ground temperatures across depths varied by site, as well as locations within sites. Permafrost thaw was generally deeper at urban sites, though again with some variation based on building aspect. The research team provided site-specific data and analysis to the community. The work was conducted by UVA PhD candidate Mirella Shaban, who will be defending her dissertation on November 20.
In September, we installed ten new sets of ground temperature and moisture monitoring equipment at five locations across town, with the goal of understanding the impact of ground moisture on permafrost stability. At each of the sites, one set of sensors is installed in an area that remains relatively dry and one in a nearby area that accumulates surface water.